Data Centre Noise Control — Guaranteed IL, Engineered Airflow
Meet boundary noise limits without compromising cooling or uptime. We design and supply silencers, acoustic louvres, barriers/enclosures and vibration isolation for hyperscale and colocation projects across Southeast Asia.
Get a 48-hour noise risk pre-assessment Download spec pack
ISO 7235 data • Octave-band IL schedules • Verified pressure-drop (ΔP) curves • C3–C5 finishes

Solutions for Data Centres
Acoustic Louvres & Screens
High free-area louvres and louvred doors for façades and rooftop plant. Optimised for airflow while delivering certified insertion loss.
Fan & Duct Silencers
Axial/centrifugal attenuators and splitter silencers sized to your duty and ΔP budget, with octave-band IL to meet boundary criteria.
Barriers & Enclosures
Compound barriers and engineered enclosures for standby gensets and chillers, with spring isolation and inertia bases.

Our Process
1. Assess
We review boundary limits, fan schedules (CFM/m³·s), and available footprint.
We review boundary limits, fan schedules (CFM/m³·s), and available footprint.
2. Model
We model octave-band IL and pressure drop to select geometry and finishes.
We model octave-band IL and pressure drop to select geometry and finishes.
3. Specify
We issue IL schedules, ΔP curves, corrosion class and submittal package.
We issue IL schedules, ΔP curves, corrosion class and submittal package.
4. Supply & Commission
Regional fabrication and install support; verification at SAT.
Regional fabrication and install support; verification at SAT.
Specification Text (extract)
Provide factory-tested silencers in accordance with ISO 7235. Minimum octave-band insertion loss to meet site boundary criteria at [nearest receptor].
Submit pressure-drop calculations at design airflow [m³/s]. Construction: galvanised or stainless steel; PPC finish as scheduled; non-hygroscopic acoustic infill with migration control;
acoustic louvres to achieve high free area at design face velocity. Vibration isolation: spring mounts with 25–50 mm static deflection as scheduled.
FAQ
How quickly can you quote?
If you share the fan schedule and boundary limits, we return a budgetary IL/ΔP package within 48 hours.
If you share the fan schedule and boundary limits, we return a budgetary IL/ΔP package within 48 hours.
Do you provide BIM?
Yes. Revit families and submittal drawings are supplied with the approved package.
Yes. Revit families and submittal drawings are supplied with the approved package.
What corrosion class is available?
C3–C5 with PPC and stainless options for marine/rooftop exposure.
C3–C5 with PPC and stainless options for marine/rooftop exposure.
Do you install?
We support regional installation and commissioning as required.
We support regional installation and commissioning as required.